2.1.1 Narrative
In conducting downgradient sampling pertaining to another Superfund site in the area (the PCE/TCE Northeast Contamination site, f.k.a. as the York Northeast Groundwater site), a distinct groundwater contaminant plume in York was discovered by the U.S. Environmental Protection Agency in the fall of 2010. Concentrations of PCE ranging from 9.6 to 32 µg/L were found in private drinking water wells. One well also contained TCE at a concentration of 5.9 µg/L. The EPA MCL for PCE and TCE in drinking water is 5 µg/L.
The EPA is continuing to provide an alternative water supply to
residents, conduct vapor intrusion sampling, and install vapor mitigation
systems where necessary. Additionally, the EPA is conducting additional soil
and groundwater sampling, attempting to identify source areas and further
delineate the groundwater plume.
2.1.2 Response Actions to Date
Met with City of York to discuss zoning outside of city limits. Anyone building outside city limits does not have access to water mains. The EPA is working with the city to make people installing their own private drinking water wells aware of the location of the contamination plumes. Ideas we are looking at include suggesting whole house filters be installed in new homes built in the area of the plumes.
Met with owner of two buildings downtown that need vapor mitigation systems installed to discuss the contamination plume and sample results from the buildings.
Met with county historical society to discuss previous business in downtown York.
Met with City officials to discuss still existing steam tunnels and utility corridors in downtown York.
Worked on access to properties in downtown York and off Nobes Road for groundwater sampling event the first week of November 2015.
2.1.3 Enforcement Activities, Identity of Potentially Responsible Parties (PRPs)
The PRP search is ongoing. No PRP has been identified to date.
2.1.4 Progress Metrics
-
Collected
approximately 56 indoor air samples
-
Collected
approximately 167 subslab soil gas samples
-
Installed 17
vapor mitigation systems
-
Collected
approximately 160 groundwater samples to further delineate the groundwater
plume (since 2014)
-
Oversight for
installation of a water main to hook approximately 10 residences to city water
-
Connected
approximately 16 residences to city water (since 2014)
-
Collected
approximately 40 soil samples to assist in finding source areas.
Sample results tables can be found in document section.
|