U.S. flag

An official website of the United States government

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

HTTPS

Secure .gov websites use HTTPS
A lock () or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Chillum PERC

Images

All Images [11]
Categories
Sketch of the area under investigation for PERC and gasoline in subsoils<br />Date Taken: <br />Category: <br />Latitude: <br />Longitude: <br />Tags:
Aerial Photograph of the area under investigation<br />Date Taken: 1/1/2000<br />Category: <br />Latitude: <br />Longitude: <br />Tags:
Soil vapor sampling with Geoprobe<br />Date Taken: 1/20/2003<br />Category: <br />Latitude: <br />Longitude: <br />Tags:
One-liter Tedlar bag<br />Date Taken: 2/3/2003<br />Category: <br />Latitude: <br />Longitude: <br />Tags:
Active soil vapor sampling from temporary sample point.  The cylindrical object in the left center of the photograph is a portable vacuum pump.  An air sample is collected by pumping air through Teflon tubing and into a Tedlar bag.<br />Date Taken: 2/3/2003<br />Category: <br />Latitude: <br />Longitude: <br />Tags:
Split active soil vapor sample configuration, showing one-liter Tedlar bags and open vacuum box.  A constant-flow pump, which is used to create a vacuum when the box is closed, is shown at the lower left.<br />Date Taken: 9/15/2003<br />Category: <br />Latitude: <br />Longitude: <br />Tags:
Groundwater Sampling Configuration, Low-Flow Sampling Method.  This configuration and sampling method was used in September, 2003, as part of the PERC investigation.<br />Date Taken: 9/15/2003<br />Category: <br />Latitude: <br />Longitude: <br />Tags:
Coring device used to drill through concrete basement slabs<br />Date Taken: 7/22/2003<br />Category: <br />Latitude: <br />Longitude: <br />Tags:
A small-diamter driven well and open protective steel casing.  Six small-diameter wells were installed during July and August, 2003, as part of the PERC investigation.  The diameter of the steel cap is approximately six inches.<br />Date Taken: 9/11/2003<br />Category: <br />Latitude: <br />Longitude: <br />Tags:
Six-liter Summa canisters.  This type of rigid-walled canister was used to collect indoor air samples in July 2003.<br />Date Taken: <br />Category: <br />Latitude: <br />Longitude: <br />Tags:
A flow regulator.  This device is attached to Summa canisters to regulate the rate at which air sample is collected.<br />Date Taken: <br />Category: <br />Latitude: <br />Longitude: <br />Tags: