West Port High School Mercury

Images

All Images [13]
Categories
Image  Description Category Date Tags
DSC02872.JPG<br />Date Taken: 2/4/2010<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags: View fromt the door of the classroom and over the over-pack container left by the Ocala Haz-Mat Team. Site Photo 2/4/2010
DSC02873.JPG<br />Date Taken: 2/4/2010<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags: OSC Andrews performing initial assessment of the spill area. Hg detection below health-based levels (3.0 ug/m^3) at several feet off the floor. Site Photo 2/4/2010
DSC02874.JPG<br />Date Taken: 2/4/2010<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags: FLA DEP and EPA OSC conducting assessment with LUMEX LIght portable mercury analyzer. Site Photo 2/4/2010
DSC02875.JPG<br />Date Taken: 2/4/2010<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags: Close-up of spill area. Site Photo 2/4/2010
DSC02876.JPG<br />Date Taken: 2/4/2010<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags: Close-up of spill area and drain by classroom eye-wash. At floor level the drain registered approximately 6.0 ug/m^3 Hg (at R Factor of 3). Site Photo 2/4/2010
DSC02877.JPG<br />Date Taken: 2/4/2010<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags: Wider angle view of spill area, sorbent, and drain. Note the brace on the side of the eye-wash was the location and frame for the mercury barometer. Site Photo 2/4/2010
DSC02879.JPG<br />Date Taken: 2/4/2010<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags: Another tight picture of the spill area, sorbent and drain below the classroom eye-wash. Site Photo 2/4/2010
DSC02882.JPG<br />Date Taken: 2/4/2010<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags: OSC conducting monitoring at the drain below the eye-wash. 6.0 ug/m^3 Hg. Site Photo 2/4/2010
DSC02887.JPG<br />Date Taken: 2/4/2010<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags: FL DEP conducting air monitoring at the mouth of the spill drain below the classroom eye-wash. Consistently detecting in the 5 to 6 ug/m^3 Hg.... Site Photo 2/4/2010
DSC02889.JPG<br />Date Taken: 2/4/2010<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags: FLA DEP conducting additional survey of floor-level around the spill drain. Site Photo 2/4/2010
DSC02895.JPG<br />Date Taken: 2/4/2010<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags: ALWAYS check your in-line filter of the LUMEX prior to use and replace as neccessary... Site Photo 2/4/2010
DSC02901.JPG<br />Date Taken: 2/4/2010<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags: Measurement at the mouth of the spill drain at 5.0 ug/m^3 (R=2). Site Photo 2/4/2010
DSC02912.JPG<br />Date Taken: 2/4/2010<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags: EPA / FLA DEP - Mission Accomplished for the Wolf Pack !!! Site Photo 2/4/2010