Biological Processors of Alabama (BPA) located in the industrial area of Decatur, Alabama and was referred to the Emergency Response and Removal Branch by the Alabama Department of Environmental Management (ADEM). BPA is a centralized waste treatment facility that collected, treated wastes from facilities throughout northern Alabama. The facility utilized oil/water separators, precipitation of wastes and neutralization in preparation for discharging to the Decatur Waste Water Treatment Plant.
The facility started operations in the Fall of 2004 and ceased operations in the Fall of 2008.
The site consists of 35 frac tanks, 16 above-ground storage tanks (ASTs), 1 tanker truck, an open pit, secondary containments, process equipments, numerous drums and totes, and many laboratory reagents. There are more than 1 million gallons of wastewaters containing hazardous substances abandoned at the site.
The site will consist of 2 phases. Phase 1 will be addressed first due to higher threats (ASTs, secondary containment, piping, containers, and soils). Phase 2, which includes frac tanks and process equipment inside building, will be addressed after Phase 1 is complete.
1) All drums and totes have been sampled.
2) Sludges and wastewaters have been removed from open-top ASTs in upper secondary containment area. Sludges are collected in sludge box which will be sent for disposal.
3) Open-top ASTs are being deconned with pressure washer.
4) Wastewaters in EQ tank in lower secondary containment will be sent off-site for treatment and disposal.
5) Solidified sludge from the pit is being sent for disposal.
6) Conduct bench tests with drums and totes to combine waste streams.
1) Remove wastewaters and sludges from PIH, Horizontal, TWT, Special Wastes, and plastic tanks.
2) Decon tanks after wastewaters and sludges have been removed. Plastic tanks may be discarded.
3) Decon or dispose of ASTs pipes.
4) Dispose of totes, drums, and containers.
5) Dispose of hazardous wastes in tanker truck.
6) Excavate contaminated soils around secondary containment area if needed.
Some ASTs and the daf unit in process area show evidence of leaks. Contents may be transported to totes or other containers.
None.
|