PCE Southeast Contamination RV001

All POL/SITREP's for this site PCE Southeast Contamination RV001
York, NE - EPA Region VII
POLREP #12
Progress - Indoor Air and Sub Slab Soil Gas Sampling
Printer Friendly  |   PDF
 
U.S. ENVIRONMENTAL PROTECTION AGENCY
POLLUTION/SITUATION REPORT
PCE Southeast Contamination RV001 - Removal Polrep

EPA Emergency Response

UNITED STATES ENVIRONMENTAL PROTECTION AGENCY
Region VII

Subject: POLREP #12
Progress - Indoor Air and Sub Slab Soil Gas Sampling
PCE Southeast Contamination RV001
A7X7
York, NE
Latitude: 40.8673915 Longitude: -97.5920867


To:
From: Susan Fisher, OSC
Date: 8/9/2015
Reporting Period: 2/2/2015 to 3/9/2015

1. Introduction
  1.1 Background
   
Site Number: A7X7    Contract Number:  
D.O. Number:      Action Memo Date: 4/11/2011
Response Authority: CERCLA    Response Type: Time-Critical
Response Lead: EPA    Incident Category: Removal Action
NPL Status: NPL    Operable Unit: 00
Mobilization Date: 9/7/2011    Start Date: 9/7/2011
Demob Date:      Completion Date:  
CERCLIS ID: NEN000706200    RCRIS ID:
ERNS No.:    State Notification: NDEQ
FPN#:    Reimbursable Account #:

1.1.1 Incident Category

CERCLA Incident Category: Time-Critical Removal Action

1.1.2 Site Description

1.1.2.1 Location

The city of York is located in the west-central portion of York County in southeast Nebraska. The Site is located to the southeast of the city of York, near the intersection of Road N and Road 12. Land use in the area is primarily residential.

1.1.2.2 Description of Threat

1.1.3 Preliminary Removal Assessment/Removal Site Inspection Results

In conducting downgradient sampling pertaining to another Superfund site in the area (the PCE/TCE Northeast Contamination site, f.k.a. as the York Northeast Groundwater site), a distinct groundwater contaminant plume in York was discovered by the U.S. Environmental Protection Agency in the fall of 2010. As a result of this discovery, the EPA completed an Abbreviated Preliminary Assessment (APA) for the Site in November 2010. Sampling conducted during the preparation of the APA identified eight residential drinking wells with concentrations of tetrachloroethene (PCE) ranging from 9.6 to 32 micrograms per liter (µg/L). Of these wells, one also contained trichloroethene (TCE) at a concentration of 5.9 µg/L.  Concentrations of carbon tetrachloride (CCL4) have been found in wells previously sampled at concentrations as high as 6.9 µg/L. The EPA’s maximum contaminant level (MCL) for both PCE and TCE is 5 µg/L.

2. Current Activities
  2.1 Operations Section
   

2.1.1 Narrative

In conducting downgradient sampling pertaining to another Superfund site in the area (the PCE/TCE Northeast Contamination site, f.k.a. as the York Northeast Groundwater site), a distinct groundwater contaminant plume in York was discovered by the U.S. Environmental Protection Agency in the fall of 2010. Concentrations of PCE ranging from 9.6 to 32 µg/L were found in private drinking water wells. One well also contained TCE at a concentration of 5.9 µg/L.  The EPA MCL for PCE and TCE in drinking water is 5 µg/L.

The EPA is continuing to provide an alternative water supply to residents, conduct vapor intrusion sampling, and install vapor mitigation systems, where necessary.  Additionally, the EPA is conducting additional soil and groundwater sampling, attempting to identify source areas and further delineate the groundwater plume. 

2.1.2 Response Actions to Date

From February 2-5, 2015, EPA employees installed 78 subslab soil gas ports in properties.  OSC Fisher gave an interview on radio stations KAWL AM 1370 and FM 104.9 discussing past activities and upcoming vapor intrusion sampling.  

No field activities from February 6, 2015 to March 2, 2015.

From March 3-5, 2015, the EPA and START collected 78 subslab soil gas samples which were analyzed in the EPA on-site mobile lab.  Approximately 14 subslab soil gas samples showed contamination above screening levels.  Twenty-eight indoor air samples were collected as well.  The summa canisters were sent to the Region 7 EPA Laboratory for analysis.  Approximately 3 indoor air samples showed concentrations above RALs. 

Vapor intrusion is being investigated in several areas in downtown York.  Locations chosen for vapor intrusion sampling are based on former dry cleaners that operated from the 1930s to the present.  Approximately seven former dry cleaner locations are currently being investigated.  These locations were identified from Sanborn fire insurance maps, York telephone directories (found in the Kilgore Memorial Library as well as the York Historical Society), and other historical sources.

2.1.3 Enforcement Activities, Identity of Potentially Responsible Parties (PRPs)

The PRP search is ongoing. No PRP has been identified to date.

2.1.4    Progress Metrics

Groundwater at the Site is contaminated with PCE, TCE and CCL4 at levels above the RAL and MCL of 5 µg/L, resulting in unacceptable exposures to area residents. 

APA sample results can be found in "Table 1 2010 Drinking Water Well Sample Results" in the document section.

Sample results from drinking water well sampling events can be found in the document section under "Table 2 Drinking Water Well Sample Results".

Indoor Air and Subslab Soil Gas sample results can be found in the document section under "Table 4 indoor Air & Sub Slab Vapor Intrusion Analytical Results".

Soil sample results can be found in the document section under "Table 3 Soil Sample Results".

  2.2 Planning Section
    2.2.1 Anticipated Activities

Groundwater sampling will continue in the area to be able to fully delineate the groundwater plume.  Additional vapor intrusion sampling is being planned. Additional soil and groundwater sampling is being planned.

2.2.1.1 Planned Response Activities

Continue to provide alternate water to affected properties.  Install vapor mitigation systems in properties with vapor intrusion results above screening levels and/or RALs.

2.2.1.2 Next Steps

The site is listed on the National Priorities List.  A remedial action is being conducted in conjunctionc with the removal action.

2.2.2 Issues

  2.3 Logistics Section
    Not applicable.

  2.4 Finance Section
    No information available at this time.

  2.5 Other Command Staff
    2.5.3 Information Officer

The EPA Community Involvement Coordinator for the Site is Tamara Freeman.

The administrative record for the Site is available for review at the Kilgore Memorial Library, 520 Nebraska Avenue, York, NE 68467.

3. Participating Entities
  3.1 Unified Command

EPA
Nebraska Department of Environmental Quality
ATSDR

3.2 Cooperating Agencies

City of York Nebraska
Four Corners Health Department
York County
York Board of Realtors

4. Personnel On Site
 

EPA Personnel working on the project (not necessarily on site):
OSC Fisher
RPM Hull
CIC Freeman
EPA Toxicologist Phillips
EPA CNSL Nazar
EPA SME Nicoski

Other:
1 ATSDR representative
2 NDEQ representatives

Administrator of the City of York
Engineer for the City of York

5. Definition of Terms
  APA -         Abreviated Preliminary Assessment
ATSDR -   Agency for Toxic Substance Disease Registry
CCL4 -      carbon tetrachloride
CIC -         community involvement coordinator
CNSL -      US EPA Counsel
CW -         City water
EPA -        Environmental Protection Agency
f.k.a. -        formerly known as
IA -            Indoor Air
MCL -        Maximum Contaminate Level
Mbl Lab -   Mobile Lab
nd -            non detect
NDEQ -     Nebraska Department of Environmental Quaility
NPL           National Priorities List
OSC -        On-Scene Coordinator
PCE -         Tetrachloroethene
PRP -         Potentially Responsible Party
RAL -         Removal Action Level
RPM -        Remedial Project Manager
SME -        Subject Matter Expert
SS -           Subslab
TCE -         Trichloroethene
µg/L -         Micrograms per Liter
µg/kg          Micrograms per kilogram
µg/ m3 -      Micrograms per cubic meter
WHF -        Whole House Filter

6. Additional sources of information
  6.1 Internet location of additional information/report

PCE
 - A hazardous substance in CERCLA section 101(14) as listed at 40 CFR section 302.4. A man-made chemical that is widely used for dry cleaning clothes and for metal degreasing. It evaporates easily into the air and has a sharp, sweet odor. Exposure to PCE at very high concentrations (particularly in closed, poorly ventilated areas) can cause dizziness, headache, drowsiness, confusion, nausea, difficulty in speaking and walking, unconsciousness and death. PCE has been shown to cause liver tumors in mice and kidney tumors in rats. It has been determined that PCE is a Class 2A carcinogen via inhalation based on long-term exposure.

TCE - A hazardous substance in CERCLA section 101(14) as listed at 40 CFR section 302.4.  A man-made chemical typically used in metal degreasing. The Agency for Toxic Substances and Disease Registry reports that inhalation exposure to TCE at very high concentrations may affect the central nervous system, with symptoms such as dizziness, headaches, confusion, euphoria, facial numbness and weakness. Recent studies have linked TCE with structural heart malformations associated with exposure during the prenatal period.

For more information on these chemicals go to:
http://www.atsdr.cdc.gov/toxprofiles/index.asp

Vapor Intrusion - Occurs when vapors produced by a chemical spill or groundwater contamination plume migrate through soil and the foundations of structures and into the indoor air. When chemicals are spilled on the ground, they will seep into the soil and make their way into the groundwater. VOCs, including PCE and TCE, produce vapors that travel through soil. These vapors can enter buildings, through cracks in the foundation, or a basement with a dirt floor, or concrete slab or crawl space.

For more information about vapor intrusion got to: http://www.epa.gov/region07/factsheets/2010/faq_about_vapor_intrusion_201002.htm

7. Situational Reference Materials
  No information available at this time.