U.S. ENVIRONMENTAL PROTECTION AGENCY
POLLUTION/SITUATION REPORT
PCE Southeast Contamination RV001 - Removal Polrep
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY
Region VII
|
Subject:
|
POLREP #19
Progress (vapor mitigation system bids)
PCE Southeast Contamination RV001
A7X7
York, NE
Latitude: 40.8673915 Longitude: -97.5920867
|
To:
|
|
From:
|
Susan Fisher, OSC
|
Date:
|
9/10/2015
|
Reporting Period:
|
9/10/2015
|
1. Introduction
|
|
1.1 Background
|
|
|
Site Number: |
A7X7 |
|
Contract Number: |
|
D.O. Number: |
|
|
Action Memo Date: |
4/11/2011 |
Response Authority: |
CERCLA |
|
Response Type: |
Time-Critical |
Response Lead: |
EPA |
|
Incident Category: |
Removal Action |
NPL Status: |
NPL |
|
Operable Unit: |
00 |
Mobilization Date: |
9/7/2011 |
|
Start Date: |
9/7/2011 |
Demob Date: |
|
|
Completion Date: |
|
CERCLIS ID: |
NEN000706200 |
|
RCRIS ID: |
|
ERNS No.: |
|
|
State Notification: |
NDEQ |
FPN#: |
|
|
Reimbursable Account #: |
|
1.1.1 Incident Category
CERCLA Incident Category: Time-Critical Removal Action
1.1.2 Site Description
1.1.2.1 Location
The city of York is located in the west-central portion of York County in southeast Nebraska. The Site is located to the southeast of the city of York, near the intersection of Road N and Road 12. Land use in the area is primarily residential.
1.1.2.2 Description of Threat
1.1.3 Preliminary Removal Assessment/Removal Site Inspection Results
In conducting downgradient sampling pertaining to another Superfund site in the area (the PCE/TCE Northeast Contamination site, f.k.a. as the York Northeast Groundwater site), a distinct groundwater contaminant plume in York was discovered by the U.S. Environmental Protection Agency in the fall of 2010. As a result of this discovery, the EPA completed an Abbreviated Preliminary Assessment (APA) for the Site in November 2010. Sampling conducted during the preparation of the APA identified eight residential drinking wells with concentrations of tetrachloroethene (PCE) ranging from 9.6 to 32 micrograms per liter (µg/L). Of these wells, one also contained trichloroethene (TCE) at a concentration of 5.9 µg/L. Concentrations of carbon tetrachloride (CCL4) have been found in wells previously sampled at concentrations as high as 6.9 µg/L. The EPA’s maximum contaminant level (MCL) for both PCE and TCE is 5 µg/L.
|
2. Current Activities
|
|
2.1 Operations Section
|
|
|
2.1.1 Narrative
In conducting downgradient sampling pertaining to another Superfund site in the area (the PCE/TCE Northeast Contamination site, f.k.a. as the York Northeast Groundwater site), a distinct groundwater contaminant plume in York was discovered by the U.S. Environmental Protection Agency in the fall of 2010. Concentrations of PCE ranging from 9.6 to 32 µg/L were found in private drinking water wells. One well also contained TCE at a concentration of 5.9 µg/L. The EPA MCL for PCE and TCE in drinking water is 5 µg/L.
The EPA is continuing to provide an alternative water supply to
residents, conduct vapor intrusion sampling, and install vapor mitigation
systems, where necessary. Additionally, the EPA is conducting additional soil
and groundwater sampling, attempting to identify source areas and further
delineate the groundwater plume.
2.1.2 Response Actions to Date
From August 30 to September 3, 2015, the EPA collected quarterly vapor intrusion samples, and collected vapor intrusion samples from ten additional properties. The EPA mobile lab was on site and analyzed approximately 75 samples; 30 samples were collected in summa canisters and sent to the Region 7 EPA laboratory for analysis. Sample results from the mobile lab for PCE were as high as 60,000 µg/L and 302.1 µg/L for TCE.
ERRS put out a bid for installation of two vapor mitigation systems at properties that showed contamination results that exceeded RALs.
On September 10, 2015, the EPA met with the ERRS contractor to conduct a walk-through with bidders of two properties that need vapor mitigation systems.
2.1.3 Enforcement Activities, Identity of Potentially Responsible Parties (PRPs)
The PRP search is ongoing. No PRP has been identified to date.
2.1.4 Progress Metrics
|
|
2.2 Planning Section
|
|
|
2.2.1 Anticipated Activities
Groundwater sampling is scheduled for the first week of November 2015.
Additional vapor mitigation systems will be installed. After bids for systems have been received, an installation date will be scheduled.
2.2.1.1 Planned Response Activities
Groundwater sampling
is scheduled for the first week of November 2015.
Additional vapor mitigation systems will also be
installed. After bids for systems have been received, an installation
date will be scheduled.
2.2.1.2 Next Steps
The site is listed on the National Priorities List. A remedial action is being conducted in conjunction with the removal action.
2.2.2 Issues
No issues at this time.
|
|
2.3 Logistics Section
|
|
|
Not applicable.
|
|
2.4 Finance Section
|
|
|
No information available at this time.
|
|
2.5 Other Command Staff
|
|
|
2.5.3 Information Officer
The EPA Community Involvement Coordinator for the Site is Tamara Freeman.
The administrative record for the Site is available for review at the Kilgore Memorial Library, 520 Nebraska Avenue, York, NE 68467.
|
3. Participating Entities
|
|
3.1 Unified Command
EPA
Nebraska Department of Environmental Quality
ATSDR
3.2 Cooperating Agencies
City of York Nebraska
Four Corners Health Department
York County
York Board of Realtors
|
4. Personnel On Site
|
|
EPA Personnel working on the project (not necessarily on site):
OSC Fisher
RPM Hull
CIC Freeman
EPA Toxicologist Phillips
EPA CNSL Nazar
EPA SME Nicoski
Other:
1 ATSDR representative
2 NDEQ representatives
Administrator of the City of York
Engineer for the City of York
|
5. Definition of Terms
|
|
APA - Abreviated Preliminary Assessment
ATSDR - Agency for Toxic Substance Disease Registry
CCL4 - carbon tetrachloride
CIC - community involvement coordinator
CNSL - US EPA Counsel
CW - City water
EPA - Environmental Protection Agency
f.k.a. - formerly known as
IA - Indoor Air
MCL - Maximum Contaminate Level
Mbl Lab - Mobile Lab
nd - non detect
NDEQ - Nebraska Department of Environmental Quaility
NPL National Priorities List
OSC - On-Scene Coordinator
PCE - Tetrachloroethene
PRP - Potentially Responsible Party
RAL - Removal Action Level
RPM - Remedial Project Manager
SME - Subject Matter Expert
SS - Subslab
TCE - Trichloroethene
µg/L - Micrograms per Liter
µg/kg Micrograms per kilogram
µg/ m3 - Micrograms per cubic meter
WHF - Whole House Filter
|
6. Additional sources of information
|
|
6.1 Internet location of additional information/report
PCE - A hazardous substance in CERCLA section 101(14) as listed at 40 CFR section 302.4. A man-made chemical that is widely used for dry cleaning clothes and for metal degreasing. It evaporates easily into the air and has a sharp, sweet odor. Exposure to PCE at very high concentrations (particularly in closed, poorly ventilated areas) can cause dizziness, headache, drowsiness, confusion, nausea, difficulty in speaking and walking, unconsciousness and death. PCE has been shown to cause liver tumors in mice and kidney tumors in rats. It has been determined that PCE is a Class 2A carcinogen via inhalation based on long-term exposure.
TCE - A hazardous substance in CERCLA section 101(14) as listed at 40 CFR section 302.4. A man-made chemical typically used in metal degreasing. The Agency for Toxic Substances and Disease Registry reports that inhalation exposure to TCE at very high concentrations may affect the central nervous system, with symptoms such as dizziness, headaches, confusion, euphoria, facial numbness and weakness. Recent studies have linked TCE with structural heart malformations associated with exposure during the prenatal period.
For more information on these chemicals go to:
http://www.atsdr.cdc.gov/toxprofiles/index.asp
Vapor Intrusion - Occurs when vapors produced by a chemical spill or groundwater contamination plume migrate through soil and the foundations of structures and into the indoor air. When chemicals are spilled on the ground, they will seep into the soil and make their way into the groundwater. VOCs, including PCE and TCE, produce vapors that travel through soil. These vapors can enter buildings, through cracks in the foundation, or a basement with a dirt floor, or concrete slab or crawl space.
For more information about vapor intrusion got to: http://www.epa.gov/region07/factsheets/2010/faq_about_vapor_intrusion_201002.htm
|
7. Situational Reference Materials
|
|
No information available at this time.
|
|
|