South Dayton Dump Site

Images

All Images [26]
Categories

Building 24 Sub-slab & Indoor Air Location B<br />Date Taken: 2/20/2015<br />Category: Site Photo<br />Latitude: 39.7247611111111<br />Longitude: -84.2184916666667<br />Tags:

Building 14 Sub-slab location A<br />Date Taken: 2/19/2015<br />Category: Site Photo<br />Latitude: 39.7275888888889<br />Longitude: -84.2181027777778<br />Tags:

Building 14 Indoor Air location B<br />Date Taken: 2/19/2015<br />Category: Site Photo<br />Latitude: 39.7276416666667<br />Longitude: -84.2180027777778<br />Tags:

Building 12 Sub-slab location SJ-B<br />Date Taken: 2/18/2015<br />Category: Site Photo<br />Latitude: 39.7324555555556<br />Longitude: -84.2200166666667<br />Tags:

Building 9 Sub-slab & Indoor Air Location A<br />Date Taken: 2/17/2015<br />Category: Site Photo<br />Latitude: 39.7281416666667<br />Longitude: -84.2180166666667<br />Tags:

Building 8 IA location D<br />Date Taken: 2/17/2015<br />Category: Site Photo<br />Latitude: 39.7288138888889<br />Longitude: -84.2177277777778<br />Tags:
Globe Equipment Building 24 1 year proficiency sampling. CRA Sub-slab sample setup with duplicate<br />Date Taken: 12/5/2014<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags:
Asphalt plant control building 
Closeup of vapor abatement system fan<br />Date Taken: 7/7/2014<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags:
Asphalt plant control building 
Indoor air sample location<br />Date Taken: 7/7/2014<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags:
Asphalt plant control building 
Sub-slab sample location leak test<br />Date Taken: 7/7/2014<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags:
Asphalt Plant control building 
Vapor abatement system on exterior of bulding<br />Date Taken: 7/7/2014<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags:
Outdoor air sample collection near vapor abatement system vent and fan outside Building 9.
<br />Date Taken: 5/20/2014<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags:
Building 9
Sub-slab sample collected from a compliance probe in foreground.
Indoor air sample with field duplicate in background. <br />Date Taken: 5/20/2014<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags:
Collection of sub-slab sample and field duplicate in Building 9.<br />Date Taken: 5/20/2014<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags:
Building 9
Leak check prior to collecting a sub-slab sample.
<br />Date Taken: 5/20/2014<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags:
Sub-slab depressurization system on Building 8
<br />Date Taken: 9/11/2013<br />Category: Site Photo<br />Latitude: 39.7248333333333<br />Longitude: -84.2183333333333<br />Tags:
Sub-Slab sample being collected from Building 12 (S&J Precision)
<br />Date Taken: 10/24/2013<br />Category: Site Photo<br />Latitude: 39.7275<br />Longitude: -84.2168333333333<br />Tags:
Air sampling being collected from a compliance probe - Building 12 (Overstreet Painting)
<br />Date Taken: 10/24/2013<br />Category: Site Photo<br />Latitude: 39.7275<br />Longitude: -84.2168333333333<br />Tags:
Sub-slab sampling in Building 9
<br />Date Taken: 10/24/2013<br />Category: Site Photo<br />Latitude: 39.7205<br />Longitude: -84.2053333333333<br />Tags:
Outside view of the SSDS fan on Building 4 at the Valley Asphalt facility
<br />Date Taken: 7/17/2013<br />Category: Site Photo<br />Latitude: 39.729<br />Longitude: -84.2196666666667<br />Tags:
SSDS in Building 4 at the Valley Asphalt plant
<br />Date Taken: 7/17/2013<br />Category: Site Photo<br />Latitude: 39.7288333333333<br />Longitude: -84.2196666666667<br />Tags:
EPA collecting a split sub-slab sample with CRA<br />Date Taken: 1/9/2013<br />Category: Site Photo<br />Latitude: 39.7206666666667<br />Longitude: -84.2093333333333<br />Tags:
Building MP on the Valley Asphalt property.  Crawl space showed PCE exceedance.  Building will be demolished.<br />Date Taken: 4/2/2013<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags:
LEL meter installed at 1903 Dryden Road<br />Date Taken: 1/24/2013<br />Category: Site Photo<br />Latitude: 39.721<br />Longitude: -84.2075<br />Tags:
Vapor Probe sampling<br />Date Taken: 7/31/2012<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags:
Sub-Slab sampling<br />Date Taken: 7/31/2012<br />Category: Site Photo<br />Latitude: <br />Longitude: <br />Tags: