Image
Category
Date
Tags
View along Avenue K upgradient toward the west.
Site Photo
2/7/2018
SSVI Pick
View of the sideyard of the house where the vapor intrusion was reported. A crawlspace access hole is located behind the sheet of plywood and concrete block. Facing southeast.
Site Photo
2/7/2018
SSVI Pick
View of the laundry-room entranceway of the house where the vapor intrusion was reported. A crawlspace vent is located between the step and the vacuum. Facing southwest.
Site Photo
2/7/2018
SSVI Pick
START takes a benzene vapor measurement (using an UltraRAE 3000 with 9.8 eV lamp and a BEN-SEP tube) inside the residence where vapor intrusion was reported. Facing north and towards the front door in the living room.
Site Photo
2/7/2018
SSVI Pick
START collects a Tedlar bag vapor sample using a vacuum box and a low flow pump. Facing southwest towards the kitchen entrance inside the living room.
Site Photo
2/7/2018
SSVI Pick
START analyzes Tedlar bag vapor samples using a Hapsite portable GC/MS analyzer inside the Seattle Comms Truck. Facing northwest. Samples were collected inside the house and from three crawlspace access points.
Site Photo
2/7/2018
SSVI Pick
START collects a 6L vacuum cannister 12-hour sample in the backyard of the residence where vapor intrusion was reported. The canister was subsequently sent to an analytical laboratory for TO-15 analysis. Facing south.
Site Photo
2/8/2018
SSVI Pick
START collects a 6L vacuum cannister 12-hour sample in the child's bedroom of the residence where vapor intrusion was reported. The canister was subsequently sent to an analytical laboratory for TO-15 analysis. Facing south.
Site Photo
2/8/2018
SSVI Pick
START collects a 6L vacuum cannister 12-hour sample in the living room of the residence where vapor intrusion was reported. The canister was subsequently sent to an analytical laboratory for TO-15 analysis. Facing south.
Site Photo
2/8/2018
SSVI Pick
START investigates a stormwater outfall for visible contamination near the south terminus of S. Jackson Street.
Site Photo
2/8/2018
SSVI Pick
START investigates a Neawanna Creek confluence for visible contamination east of the eastern terminus of Avenue K.
Site Photo
2/8/2018
SSVI Pick
START investigates a Neawanna Creek confluence for visible contamination east of the eastern terminus of Avenues K and M.
Site Photo
2/8/2018
SSVI Pick
START investigates a Neawanna Creek confluence for visible contamination east of the eastern terminus of Avenue M.
Site Photo
2/8/2018
SSVI Pick
START investigates a runoff "feeder" creek for visible contamination near the eastern terminus of Avenue K.
Site Photo
2/8/2018
SSVI Pick
START investigates a runoff "feeder" creek for visible contamination near the eastern terminus of Avenues K and M.
Site Photo
2/8/2018
SSVI Pick
START investigates a runoff "feeder" creek for visible contamination near the eastern terminus of Avenue K.
Site Photo
2/8/2018
SSVI Pick
Approximate extent of former 500 gallon steel septic tank marked with blue pin-flags and white paint, as described by the owner of the residence at 911 Avenue K.
Site Photo
2/8/2018
SSVI Pick
Side of house with vapor intrusion. Area of former 500 gallon steel septic tank marked with blue pin-flags and white paint, and the natural drain field to the right.
Site Photo
2/8/2018
SSVI Pick