1. Introduction
|
|
1.1 Background
|
|
|
Site Number: |
|
|
Contract Number: |
|
D.O. Number: |
|
|
Action Memo Date: |
|
Response Authority: |
CERCLA |
|
Response Type: |
Emergency |
Response Lead: |
EPA |
|
Incident Category: |
|
NPL Status: |
|
|
Operable Unit: |
|
Mobilization Date: |
3/7/2011 |
|
Start Date: |
3/7/2011 |
Demob Date: |
3/7/2011 |
|
Completion Date: |
|
CERCLIS ID: |
|
|
RCRIS ID: |
|
ERNS No.: |
969410 |
|
State Notification: |
|
FPN#: |
|
|
Reimbursable Account #: |
|
1.1.1 Incident Category
1.1.2 Site Description
The incident was located at the NTR Metals Dallas headquarters where precious metals are recycled and refined using multiple methods including electrolytic recovery.
1.1.2.1 Location
The site is located in a mixed use, light industrial section of Dallas TX, located about 7 miles North of downtown Dallas off of Interstate 35.
1.1.2.2 Description of Threat
The facility uses and stores nitric acid of various concentrations.
1.1.3 Preliminary Removal Assessment/Removal Site Inspection Results
|
2. Current Activities
|
|
2.1 Operations Section
|
|
|
2.1.1 Narrative
EPA mobilized to the site located north of downtown Dallas. EPA observed that the rectifier unit, which powers a set of electrolytic vats, had malfunctioned resulting in a fire. The fire compromised two 100 gallon electrolytic vats, resulting in the release of a solution containing 5% nitric acid into secondary containment. Dallas Fire and Haz-Mat responded to the incident and applied water to extinguish the fire. The use of water during the fire fighting efforts caused some of the nitric acid solution/firewater to overflow from the secondary containment and onto the surrounding floor. The fire water was contained to the processing room were the fire began and the nitric acid solution did not migrate off-site. The fire began early the morning of 7 March, 2011 and was declared extinguished about four hours later at approximately 0630.
|
|
2.2 Planning Section
|
|
|
|
|
2.3 Logistics Section
|
|
|
No information available at this time.
|
|
2.4 Finance Section
|
|
|
No information available at this time.
|
|
2.5 Other Command Staff
|
|
|
No information available at this time.
|
3. Participating Entities
|
|
No information available at this time.
|
4. Personnel On Site
|
|
No information available at this time.
|
5. Definition of Terms
|
|
No information available at this time.
|
6. Additional sources of information
|
|
No information available at this time.
|
7. Situational Reference Materials
|
|
No information available at this time.
|