1.1.1 Incident Category
Time-Critical Removal
1.1.2 Site Description
Most communities across Nebraska at one time had access to a high-capacity grain storage facility owned and operated by the U.S. Department of Agriculture (USDA) in which carbon tetrachloride (CCl4) was used as a grain fumigant. These fumigation processes often resulted in a CCl4 release to groundwater. CCl4 and the products of its degradation (chloroform and dichloromethane) have been found to exert detrimental effects on human health and have been classified as potential carcinogens.
The former Aurora high-capacity grain storage facility was located at the northeast corner of the 1st Street and East 12th Road intersection in Aurora, Nebraska. Well sampling data collected from area drinking water wells indicate that CCl4 may have been released to groundwater during the operation of this facility. The contaminated residential drinking water wells associated with the Aurora Groundwater site are located primarily in the southeast of Aurora, Nebraska, with the identified contamination along East 12th Road southeast of the city.
Investigations by the U.S. Environmental Protection Agency and Nebraska Department of Environmental Quality have focused on determining the extent of groundwater contamination, comprehensively characterizing potential receptors (domestic and municipal wells), and evaluating probable source areas. Volatile organic compounds (VOC) were found in seven domestic wells east of town, outside city limits, and in one municipal well in northern Aurora. Concentrations of carbon tetrachloride (CCl4) were above federal maximum contaminant levels (MCL) of 5 micrograms per liter (µg/L) in five of the domestic wells. The municipal well contained low levels of the chlorinated solvent tetrachloroethene (PCE).
During a follow-up investigation, property owners were asked whether they had installed any in-home water treatment systems, and if so, samples were collected before (pre-) and after (post-) the treatment system. Two of the five previously sampled domestic wells contained CCl4 in the post-treatment sample at concentrations above the EPA MCL of 5µg/L. The samples collected indicated concentrations of 63µg/L, and 8.4µg/L respectively. In December, 2013, a plumbing contractor from Chapman, Nebraska, was contracted by the EPA to install whole house water treatment systems at two residences. Each whole house water treatment system consists of an in-line housing containing one sediment filter and an additional in-line housing containing one carbon filter. The purpose of this system is to filter sediment and reduce dissolved organics in groundwater prior to consumption or other domestic use.
In March 2014, confirmation samples collected at the two residences indicate that the whole house filtration system was effective at reducing CCl4 concentrations to levels below the EPA MCL of 5µg/L in the post-treatment water at one home. Samples collected from the second home indicate that CCl4 concentrations in post-treatment water are still above MCL (at 34µg/L). The EPA is planning to install an additional carbon filtration unit at the second home to further reduce CCl4 concentrations.
1.1.2.1 Location
Aurora, Hamilton County, Nebraska
1.1.2.2 Description of Threat
See Site Description
1.1.3 Preliminary Removal Assessment/Removal Site Inspection Results
See Site Description
|
|
|
2.1.1 Narrative
On January 7, 2014, a plumbing contractor from Chapman, Nebraska, was contracted by the EPA to install whole house water treatment systems at two residences. Each whole house water treatment system consists of an in-line housing containing one sediment filter and an additional in-line housing containing one carbon filter. The purpose of this system is to filter sediment and reduce dissolved organics in groundwater prior to consumption or other domestic use.
2.1.2 Response Actions to Date
Installation of whole house water treatment systems at two residences.
2.1.3 Enforcement Activities, Identity of Potentially Responsible Parties (PRPs)
None at this time.
2.1.4 Progress Metrics
Waste Stream |
Medium |
Quantity |
Manifest # |
Treatment |
Disposal |
No waste generated |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|